Application Notes Pages

Particle Shape Analysis of Long Glass Fibers

APPLICATION NOTE: AN-009 Particle Measurement Technologies.  How are they different? This article analyses some large, long glass fibers by applying some of the features and comparisons of the Pi Sentinel PRO. Running the glass fibers involves 34,000 particles and ends up with 32 different histograms. There are many different shape parameters of [...]

2024-12-20T18:20:06+00:00September 1st, 2024|Comments Off on Particle Shape Analysis of Long Glass Fibers

Particle Shape Analysis of Coal Powder

APPLICATION NOTE: AN-008 Particle Measurement Technologies.  How are they different? This article describes how the Pi Sentinel PRO can be used to analyze a coal sample by looking at all the different shape measures. It can be used to obtain many histograms of factors like Size, Circularity and Smoothness. The software has [...]

2024-12-20T18:20:12+00:00September 1st, 2024|Comments Off on Particle Shape Analysis of Coal Powder

Particle Shape Analysis of Stem Cells

APPLICATION NOTE: AN-007 Particle Measurement Technologies.  How are they different? Stem cells are interesting because they are undifferentiated, and eventually they differentiate into particular cell types. There is a large amount of research going into stem cells and how they can help with therapeutics. Analyzing them using Pi Sentinel PRO can aid [...]

2024-12-20T18:20:18+00:00September 1st, 2024|Comments Off on Particle Shape Analysis of Stem Cells

Importance of Particle Size and Shape in Dissolution of Multi-Component Drug Delivery Systems

APPLICATION NOTE: AN-006 Particle Measurement Technologies.  How are they different? Purpose The particle size and particle shape of multi-component controlled release drugs must be considered during their dissolution of as a function of time. Though the size and shape of the particles are well known when the capsules are filled, oftentimes, [...]

2024-12-20T18:20:26+00:00September 1st, 2024|Comments Off on Importance of Particle Size and Shape in Dissolution of Multi-Component Drug Delivery Systems

How Particle Shape Affects HPLC Column Packing and Performance | ParticleShape.com

Particle Measurement Technologies.  How are they different? When it comes to High Performance Liquid Chromatography (HPLC), most people focus on particle size. But ignoring particle shape can seriously hurt your column's packing quality, flow consistency, and chromatographic performance. In this article, we explain why particle shape matters for HPLC columns, how Dynamic Image [...]

2025-04-27T21:14:02+00:00September 1st, 2024|Comments Off on How Particle Shape Affects HPLC Column Packing and Performance | ParticleShape.com

Importancia de la FORMA, MEDIDA y CONCENTRACION de las partículas en el proceso de fabricación y producto final

APPLICATION NOTE: AN-004-ESP Particle Measurement Technologies.  How are they different? Introducción El análisis de partículas juega un papel clave en la industria farmacéutica, tanto en la eficacia y fabricación de medicamentos como en la calidad del producto final. El tamaño de las partículas puede afectar la disolución de un excipiente o [...]

2024-12-20T18:20:39+00:00September 1st, 2024|Comments Off on Importancia de la FORMA, MEDIDA y CONCENTRACION de las partículas en el proceso de fabricación y producto final

How Particle Shape Analysis Impacts Manufacturing Process and Final Product

APPLICATION NOTE: AN-004 Particle Measurement Technologies.  How are they different? How Particle Shape Analysis Impacts Manufacturing Process and Final Product. Particle analysis plays a key role in the pharmaceutical industry in both product efficacy and manufacturing. Particle size can impact the dissolution rate of an excipient or active pharmaceutical ingredient (API) [...]

2024-12-20T18:08:50+00:00September 1st, 2024|Comments Off on How Particle Shape Analysis Impacts Manufacturing Process and Final Product

Dynamic Image Analysis of suspended liquid particles

APPLICATION NOTE: AN-003 Particle Measurement Technologies.  How are they different? Irregularly shaped particles require analysis with random orientation to ensure accurate results. Introduction In various industries, it is important to measure the size of liquid particles in a suspension. These could be as simple as oil droplets suspended in water [...]

2024-12-20T18:08:45+00:00August 30th, 2024|Comments Off on Dynamic Image Analysis of suspended liquid particles

The Importance of Random Orientation When Measuring Particle Shape

APPLICATION NOTE: AN-002 Particle Measurement Technologies.  How are they different? Irregularly shaped particles require analysis with random orientation to ensure accurate results. Introduction Particle shape is becoming more and more recognized in industry as a desirable way to monitor many industrial materials and processes. In many applications, the circularity of [...]

2024-12-20T18:08:38+00:00August 30th, 2024|Comments Off on The Importance of Random Orientation When Measuring Particle Shape

Particle Shape Analysis of Fiber Particles

APPLICATION NOTE: AN-001 Particle Measurement Technologies.  How are they different? Introduction Automated image analysis has been developed to provide users with a more accurate measurement of their particles. For many years, particle size analyzers have rendered results with the assumption that all measured particles are spherical. However, in many applications, the [...]

2024-12-20T18:08:32+00:00August 30th, 2024|Comments Off on Particle Shape Analysis of Fiber Particles
Go to Top