For more than 60 years, geologists and frac sand producers have graded grain shape by holding particles up against the Krumbein and Sloss chart. The method is simple and widely understood, but it depends on the operator’s eye and only covers a handful of grains. This page shows how the chart’s two axes, sphericity and roundness, can be translated into automated shape measurements from dynamic image analysis, and then applies that translation to a real #20/40 bauxite proppant sample.

Loose sand grains under a microscope beside the Krumbein and Sloss chart of sphericity versus roundness

What Is the Krumbein and Sloss Chart?

William C. Krumbein (1902–1979) was a geologist known for bringing mathematics and quantitative methods into sedimentology. With L. L. Sloss, he published the shape comparison chart in Stratigraphy and Sedimentation (W. H. Freeman, 1963). It has been known as the Krumbein and Sloss (K&S) chart ever since, and proppant standards such as ISO 13503-2 and API RP 19C still use it to grade the sphericity and roundness of frac sand.

The chart has two axes:

These are two separate properties. A grain can be elongated (low sphericity) yet have smooth, worn edges (high roundness), or be nearly equant (high sphericity) with sharp, angular corners (low roundness).

In practice, an analyst views grains under a microscope, compares each one to the 20 reference silhouettes on the chart, and assigns the closest sphericity and roundness values.

Four sand grains selected for visual comparison against the Krumbein and Sloss chart

Limitations of Visual Comparison

When it was introduced, the K&S chart was a real step forward. It gave geologists a common language for describing grain shape. Visual comparison, however, has three built-in weaknesses:

Four grains with visual Krumbein and Sloss estimates of (0.9, 0.3), (0.7, 0.3), (0.9, 0.5) and (0.1, 0.9) for roundness and sphericity

Automating Shape Measurement with Dynamic Image Analysis

Dynamic image analysis (DIA) captures images of particles as they move past a camera and measures the size and shape of each one. A single run can measure tens of thousands of particles in minutes, which addresses each limitation of the visual method:

Few published methods explain how to move an existing visual specification such as the K&S chart onto an automated instrument. The rest of this page walks through one way to do it.

Portable dynamic image analyzer in a rugged case next to the Krumbein and Sloss chart

Translating the Chart into Measurable Shape Parameters

The first step was to number the 20 reference particles on the chart so each could be measured individually.

Krumbein and Sloss comparison chart with sphericity from 0.3 to 0.9 on the Y-axis and roundness from 0.1 to 0.9 on the X-axis

Krumbein and Sloss chart with the 20 reference particles numbered 1 to 20

Looking across the chart suggests what each axis represents. Moving right along a row (for example, particles #16 to #20), the grains become smoother while their elongation stays about the same. Moving up a column (for example, from #1 to #16), the grains become less elongated and their length-to-width ratio approaches 1:1.

A high-resolution scan of the chart was then processed with Particle Insight dynamic image analysis software. Each reference particle was measured for circularity, smoothness, and Feret aspect ratio, and the results were tabulated.

Particle Insight software analyzing a scanned Krumbein and Sloss chart, with a Feret aspect ratio value next to each particle

Table comparing Krumbein and Sloss roundness and sphericity with Particle Insight smoothness, circularity and aspect ratio for particles 1 to 20

Circularity Alone Does Not Match Roundness

It would be convenient if Particle Insight circularity simply increased with K&S roundness, but it does not. In several rows, circularity drops as roundness increases from left to right, so circularity on its own cannot stand in for the X-axis.

Krumbein and Sloss chart beside the Particle Insight circularity value for each of the 20 reference particles

Smoothness Does Not Match Sphericity

Smoothness does not track sphericity either. Moving up the chart toward higher sphericity, some particles show lower smoothness values, not higher ones.

Krumbein and Sloss chart beside the Particle Insight smoothness value for each of the 20 reference particles

Aspect Ratio Matches Sphericity

Aspect ratio does follow the Y-axis. Particles in the 0.3 sphericity row have aspect ratios of roughly 2.2 to 2.7, while particles in the 0.9 row fall to roughly 1.2 to 1.3.

Krumbein and Sloss chart beside Particle Insight aspect ratio values, which fall from about 2.2 to 2.7 at sphericity 0.3 to about 1.2 to 1.3 at sphericity 0.9

The result: K&S sphericity (Y-axis) can be replaced with aspect ratio, and K&S roundness (X-axis) can be approximated with a combination of circularity and smoothness.

Practical Example: #20/40 Bauxite Frac Sand

To test the conversion, we analyzed a commercially sold synthetic bauxite proppant graded as #20/40. This is a medium-strength ceramic proppant designed for oil and gas wells with closure pressures up to 10,000 psi. The #20/40 grade means the grains should pass a 20-mesh sieve (850 µm opening) and be retained on a 40-mesh sieve (425 µm opening).

Sieve grading separates particles by stacking screens and weighing what each one retains. It reports how much material passes each opening, but it says nothing about grain shape, and an elongated grain can pass through an opening smaller than its length.

Grain size analysis table for #20/40 bauxite proppant beside sieve mesh and stacked test sieves

Size Results and Sieve Correlation

Many specifications are still written around sieve results, so the dynamic image analysis results were reported both as equivalent circular area (ECA) diameter and as a sieve-correlated distribution. In this run, 1,620 particles were measured, with a mean ECA diameter of 724 µm and a number-based D10–D90 of 623 to 841 µm. This is consistent with the #20/40 grade.

Because the instrument reports sieve-equivalent results along with shape data, labs can keep their existing size specifications while moving away from manual sieving.

Particle Insight ECA diameter and sieve-correlated histograms with a sample summary for 1,620 frac sand particles, mean diameter 724 µm

Individual particle images show that while many grains are well rounded, some are angular or noticeably elongated. A sieve test would not reveal this.

Thumbnail images of bauxite frac sand particles, most well rounded and some angular or elongated

Filtering the Sample by K&S Shape Class

With the chart translated into measurable parameters, a target shape class can be applied directly to the sample. For this example, we selected reference particles #12–#15 and #17–#20, which cover sphericity 0.7 to 0.9 and roundness 0.3 to 0.9. Their measured aspect ratio, circularity, and smoothness values define the acceptance window.

Krumbein and Sloss chart with particles 12 to 15 and 17 to 20 highlighted, alongside their aspect ratio, circularity and smoothness values

Those limits were entered as filter criteria in the Particle Insight software. The software then reported the particle listing, thumbnail images, and size histogram for only the particles that fall inside the target shape class. In effect, this is an automated K&S grade based on thousands of particles instead of 20.

Particle Insight filter criteria set to circularity, smoothness and aspect ratio limits, with matching particle images, particle listing and size histogram

Key Takeaways

For more on how particle shape affects proppant performance, see Can Particle Imaging Unlock More Durable Sands for Hydraulic Fracturing? To see this analysis on your own frac sand or sediment samples, request a demo of the Raptor dynamic image analyzer.

Leave a Reply